Background

Reformer Burner Burner

Direct supply from the manufacturer
Order phone:+86-189 2123 2972
E-mail:zhangjiahao@chinayanxin.com

Detail

The burner of the reformer combustion device is a new type of burner designed and manufactured by our company. At present, the reforming reaction feed heating furnace is generally a four-in-one box furnace. The U-shaped furnace tube bundles are arranged side by side, and the burners are symmetrical. distributed on the opposite furnace side walls. The burner flame is generally round and relatively burning, with a longer flame length to distribute the heat evenly in the furnace in a small amount. This type of burner generally adopts the method of staging fuel supply, which can meet the requirements of NOx emission and obtain a longer flame. Combustion-supporting air is generally natural ventilation, and a muffler needs to be installed.

Technical Characteristics Sheet


Capability MW 0.8-2.0
Low calorific value of fuel gas KJ/Nm3
33730~52110
Fuel Gas Temperature (Celsius) >30
Fuel gas pressure MPa 0.1
Air supply form Forced ventilation, natural ventilation
Air Excess Coefficient% 1.1-1.15
Flame Shape Circle
Installation Location Furnace Wall
Note: product specifications can be specially designed according to support


Pre-hydrogenation feed heating furnace, tower bottom reboiler burner Pre-hydrogenation feed heating furnace, tower bottom reboiler are generally vertical tube type cylindrical furnaces or vertical tube type square box furnaces, and most of the burners are Choose a gas-fired or combined oil-gas burner with a circular flame. This type of burner can be suitable for mechanical ventilation less than 500Pa, and can also adapt to natural ventilation with a bottom negative pressure of about 80Pa.

Technical Characteristics Sheet

Capability MW 0.8-2.5
Low calorific value of fuel oil KJ/KG ~42000
Fuel Oil Viscosity cSt ≤50
Fuel oil pressure MPa 0.6-0.8
Atomizing Steam Temperature (Celsius) ~200-280
Atomizing steam pressure MPa 0.7-0.9
Low calorific value of fuel gas KJ/Nm3 33730~52110
Fuel Gas Temperature (Celsius) >30
Fuel gas pressure MPa 0.1
Air supply form Forced Ventilation/Natural Ventilation
Air Excess Coefficient% 1.1-1.15 (gas) 1.2-1.3 (oil)
Flame Shape Circle
Installation Location Stove
Note: product specifications can be specially designed according to support